Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/25645
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFathalbab, Sara Hassan Mohammed-
dc.contributor.authorSupervisor, - Seifeldeen Ahmed Mohamed Elragouba-
dc.date.accessioned2021-01-20T11:27:05Z-
dc.date.available2021-01-20T11:27:05Z-
dc.date.issued2020-10-01-
dc.identifier.citationFathalbab, Sara Hassan Mohammed.Evaluation of Glucose Level in Serum and Plasma Using Different Anticoagulants at Room Temperature\Sara Hassan Mohammed Fathalbab;Seifeldeen Ahmed Mohamed Elragouba.-Khartoum:Sudan University of Science & Technology,College of Medical Laboratory Science,2020.-44p.:ill.;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/25645-
dc.descriptionThesisen_US
dc.description.abstractBack ground: Glucose is key to keeping the mechanisms of the body in top working order. Along with fats, glucose is one of the body's preferred sources of fuel. Glucose levels that are unhealthy or out of control can have permanent and serious effects. Objective: To measure blood glucose level storage in different anticoagulants at room temperature. Methodology: The study was conducted in Khartoum state from the period of March to September 2020. Including 60 healthy volunteers age range between 20 to 60 years old. The blood samples were dispended into different containers (fluoride oxalate, sodium citrate, lithium heparin and plain container). The glucose level was measured initially (at zero time) after 2, 4, 6 and 8 hours in the plasma and serum using colorimetric method (glucose oxides) then the data obtained were analyzed using (SPSS) in computer program. Results: The result show that the stability of blood glucose level in fluoride oxalate up to 4 hours (P-value ≥ 0.005) while in heparin and sodium citrate and serum up to 2 hours (P-value ≥ 0.005). Conclusion: From the result it was conclude that fluoride oxalate is more suitable anticoagulant for blood glucose estimation.en_US
dc.description.sponsorshipSudan University of Science @ Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science & Technologyen_US
dc.subjectGlucose Levelen_US
dc.subjectSerum and Plasmaen_US
dc.subjectAnticoagulantsen_US
dc.titleEvaluation of Glucose Level in Serum and Plasma Using Different Anticoagulants at Room Temperatureen_US
dc.title.alternativeتقويم مستوي سكر الجلكوز في مصل وبلازما الدم باستخدام موانع تجلط مختلفة في درجة حرارة الغرفةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Laboratory Science

Files in This Item:
File Description SizeFormat 
Evaluation of Glucose..........pdfResearch709.18 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.