Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/2511
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAHMED , HALA JAFAR ALAMIN
dc.contributor.authorSupervisor,- BABIKER OSMAN ElBASHIR
dc.date.accessioned2013-11-27T11:21:37Z
dc.date.available2013-11-27T11:21:37Z
dc.date.issued2006-05-01
dc.identifier.citationAHMED , HALA JAFAR ALAMIN . Hardness Improvement of Teeth Filling Material (Amalgam) by Using He-Ne Laser 632.8nm and Diode Laser 675nm / HALA JAFAR ALAMIN AHMED ; BABIKER OSMAN ElBASHIR .- Khartoum : sudan university of scince and technology , Institute Of Laser, 2006. 46P. : ill ; 28cm .- M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/2511
dc.descriptionThesisen_US
dc.description.abstractIn this research we are studied the hardness of the amalgam teeth filling material by utilizing Brinell harness test apparatus. Several tests were carried out on different amalgam mixtures that were subjected to irradiation for the two minutes of both He-Ne lasers at wavelength 632.8 nm, 1 mW power, Omega laser with wavelength 675 nm, at a power 15 mW. The samples were left for different time intervals before hardness test were carried out. Some other samples were prepared for test without irradiation, and then they were tested for hardness at different intervals also. The samples were then compared to emphasize the effect of laser on the value of hardness. The results appeared the increases of observation in the hardness of the samples irradiated by two lasers rather than the samples without irradiation. ‫.‪laser 1 mW‬‬ ‫‪All of the samples irradiated by two lasers needed to 6 hours only‬‬ ‫‪to reach the value of hardness equally 30 hours for those samples‬‬ ‫.‪without irradiated‬‬ ‫‪‫‪The samples irradiated by Diode laser 15 mW appear the‬‬ ‫‪increasing of the hardness more than the samples irradiated by He-Ne‬‬ ‫.‪laser 1 mW‬‬ ‫‪All of the samples irradiated by two lasers needed to 6 hours only‬‬ ‫‪to reach the value of hardness equally 30 hours for those samples‬‬ ‫.‪without irradiated‬‬en_US
dc.description.sponsorshipsudan university of scince and technologyen_US
dc.language.isoenen_US
dc.publishersudan university of scince and technologyen_US
dc.subjectamalgamen_US
dc.subject‫‪ Diode laser‬‬en_US
dc.titleHardness Improvement of Teeth Filling Material (Amalgam) by Using He-Ne Laser 632.8nm and Diode Laser 675nmen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Laser

Files in This Item:
File Description SizeFormat 
Hardness Improvement of ....pdfTitle302.36 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research2.96 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.