Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/24555
Title: Assessment of Radiation Dose of Pediatric and Adult patients for Computed Tomography Examination
Other Titles: تقييم الجرعات الاشعاعية للاطفال و الكبار من المرضي في فحوصات الاشعة المقطعية
Authors: Ahmed, Rufida Elbushra Eisa
Supervisor, -Mohamed Elfadil Mohamed
Co-Supervisor, -Ikhlas Abdalaziz Ahmed
Keywords: Medical Radiologic Sciences
Medical Physics
Radiation Dose of Pediatric
Adult patients
Issue Date: 1-Sep-2019
Publisher: Sudan University of Science and Technology
Citation: Ahmed, Rufida Elbushra Eisa.Assessment of Radiation Dose of Pediatric and Adult patients for Computed Tomography Examination \ Rufida Elbushra Eisa Ahmed ; Mohamed Elfadil Mohamed .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2019.-87p.:ill.;28cm.-Ph.D.
Abstract: The important of this study comes from the increased number of CT procedures to adult and pediatric as CT consider invasive investigation. Patient data for both male and female collected from four different hospital and centers in Khartoum which using different CT scanner modalities. The data of this study were collected from Alya Hospital (Toshiba, 64 slice), Ibn Alhitham specialist (Toshiba, 4 slice), Alzytouna Hospital (Toshiba, 64 slice) and Modern center (GE, 16 slice). it preformed for brain and chest in adult and pediatric patients Comparing the dose parameters among the two exams for all hospitals for brain the CTDIvol, DLP and ED was 76.82 ± 16.07, 2199.45 ± 1789.7 and 4.62 ± 3.76 respectively, while for CT chest was 32 ± 11.33, 837.59 ± 338.54 and 11.75 ± 4.8 respectively in adults. When Comparing the dose parameters(CTDIvol, DLP and ED) among the two exams for all hospitals for brain the CTDIvol, DLP and ED was 53.4 ± 9.7, 861.9 ± 268 and 7.58 ± 2.83 respectively, while for CT chest was 8.69 ± 2.78, 302.22 ± 161.75 and 7.8 ± 4.05 respectively for pediatric. Finally the radiographic data show that ED for adult male were higher than adult female as it is for pediatric male expect the CTDIv were higher for pediatric females than males.
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/24555
Appears in Collections:PhD theses :Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Radiation ......pdfResearch2.26 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.