Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/23495
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbdulla, Esra Abdulla Mohammed-
dc.contributor.authorSupervisor, -Suhaib Mohamedsalih Ahamed Alameen-
dc.date.accessioned2019-10-13T09:39:12Z-
dc.date.available2019-10-13T09:39:12Z-
dc.date.issued2019-01-28-
dc.identifier.citationAbdulla, Esra Abdulla Mohammed . Evaluation of Patients Effective Radiation Dose during Orthopedic Surgery \ Esra Abdulla Mohammed Abdulla ; Suhaib Mohamedsalih Ahamed Alameen .- Khartoum : Sudan University of Science and Technology , College of Medical Radiologic Science , 2019.- 58p. :ill;28cm.- M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/23495-
dc.descriptionThesisen_US
dc.description.abstractThis study aimed to evaluation of patients radiation dose in orthopedic surgery in Khartoum state . A total of 91 patient from orthopedic surgery conducted using mobile c-arm fluoroscopic from three hospitals ,of period from July to November of 2018. To obtained formation of patients during orthopedic surgery used mobile C-arm fluoroscopy ,to recorded the demographic data (gender, age ,weight, hight) . The results presented as mean ± SD were the mean of ESAK was (mean ±0.31 SD) and mean of ED found (mean ±0.29 SD), and the mean ESAK(0.32), mean ED (0.30 mSv) of male higher than female mean ESAK (0.30) mean ED(0.27 mSv) . Compared the dose between all hospitals found that the dose in hospital B (0.32 mSv) was higher than the dose in hospital C (0.29 mSv) and hospital A ( 0.26 mSv). The mean effective dose in present study (0.29 mSv) was lower than mean effective dose from national and international studies (0.46 mSv) and (2.90 mSv), and international organizations ICRP (1.3 mSv) and IAEA (1-3 mSv). So the study recommended that the patients should be positioned in suitable distance from the x-ray tube to minimize patient doses .en_US
dc.description.sponsorshipSudan University of Science & Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectMedical Physicsen_US
dc.subjectEvaluation of Patients Effective Radiationen_US
dc.subjectDose during Orthopedic Surgeryen_US
dc.titleEvaluation of Patients Effective Radiation Dose during Orthopedic Surgeryen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Evaluation of Patients .. .pdfResearch3.38 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.