dc.identifier.citationBakiet, Tayfour Hassan Saeed . Estimation of Effective Dose for Abdominal Organs during Computed tomography \ Tayfour Hassan Saeed Bakiet ; Hussein. Ahmed. Hassan .- Khartoum : Sudan University of Science and Technology , College of Medical Radiologic Science , 2019.- 74 p. :ill;28cm.- M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/23231-
dc.descriptionThesisen_US
dc.description.abstractThe aim of this study to estimate the radiation dose received by the patients during abdomen CT examinations. A total of 60 adult patients undergoing abdominal CT scanning exams were estimated using CTDIvol, dose length product (DLP) and effective dose (E) and evaluate effective dose and organs dose by using CT expo version 2.5 software. Also this study revealed that the mean effective dose for abdomen in hospital (A), hospital (B) and hospital (C) was (7.6)mSv, (5.3) mSv and (6.3) mAs respectively. The mean of DLP for in hospital (A), hospital (B), and hospital (C) was (450) mGy*cm, (410.95) mGy*cm and (380) mGy*cm respectively. The mean CTDIvol for abdomen in hospital (A), hospital (B) and hospital (C) was (9.9) mGy, (8.8) mGy and (7.3) mGy respectively The result of this study revealed that the mean equivalent dose for abdomen organs, stomach was (12.23) mSv, spleen was (11.99) mSv, pancreas was (9.8) mSv and adrenal gland was (9.158) mSv. And the organ doses were estimated using measurements of CT dose indexes (CTDI), exposure-related parameters, and the ImPACT spreadsheet based on NRPB conversion factors. Light variation of organ doses among three hospitals was observed for similar CT examinations. These variations largely originated from different CT scanning protocols used in different three hospitals. The organ doses in this studyen_US
dc.description.sponsorshipSudan University of Science & Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectMedical Physicsen_US
dc.subjectEstimation of Effective Doseen_US
dc.subjectAbdominal Organs during Computed tomographyen_US
dc.titleEstimation of Effective Dose for Abdominal Organs during Computed tomographyen_US
dc.title.alternativeتقدير الجرعة الفعالة للأعضاء البطنية أثناء التصوير المقطعيen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Estimation of Effective .... .pdfResearch3.19 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.