Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/22300
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAltyieb, Yagoub Abdalla Abdallrahman
dc.contributor.authorSupervisor, -Mohamed Mohammed Omer Mohamed Yousef
dc.contributor.authorCo-Supervisor, -Mona. Ahmed Mohamed Aboshanab
dc.date.accessioned2019-02-03T10:56:59Z
dc.date.available2019-02-03T10:56:59Z
dc.date.issued2018-09-24
dc.identifier.citationAltyieb, YagoubAbdallaAbdallrahman .Assessment of Left Ventricular Function in Hemodialysis Patients Using Tran’s Thoracic Echocardiography \ YagoubAbdallaAbdallrahman Altyieb ; Mohamed Mohammed Omer Mohamed Yousef .- Khartoum : Sudan University of Science and Technology , College of Medical Radiologic Science , 2018 .- 127p. :ill;28cm.- PhDen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/22300
dc.descriptionThesisen_US
dc.description.abstractThe aim of this study was to investigate the value of echocardiography in assessment of the left ventricular functions of long-standing hemodialysis patients. It was done in the renal center in Sinnar Teaching Hospital in echocardiography department using with sector probe of 2.5 mega hertiz. It included 200 cases under regular hemodialysis, using questioner included patient personal data, and echocardiography findings and the data was analyzed using computer programs for analysis (SPSS).The results of this study revealed that according to 99% of the patients had a thick septum, 81% thick posterior wall, 76% dilated cardiomyopathy, 37% impaired ejection fraction, 21% reduced stroke volume, 19% impaired cardiac output, 13% tachycardia, and 20% reduced wall motion. This study cleared that age had negative correlations with Septum, Posterior wall, COP, and a positive correlation with, LVD, EF, FS, and heart rate. In related Weight levels show negative correlations with heart rate, posterior wall, EF, and fractioning shorting, stroke volume and a positive correlation with LVD, and Septum thickness, COP, stroke volume, but the Duration showed negative correlation with LVD, COP, stroke volume, and FS, and positive correlation septum thickness, posterior wall thickness, Ejection fraction, and HR. This study concluded that echocardiography can be used for follow up hearts of these patients and adjust the suitable time for an interventionen_US
dc.description.sponsorshipSudan University of Science & Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectUltrasonographyen_US
dc.subjectLeft Ventricular Functionen_US
dc.subjectHemodialysis Patientsen_US
dc.subjectTran’s Thoracic Echocardiographyen_US
dc.titleAssessment of Left Ventricular Function in Hemodialysis Patients Using Tran’s Thoracic Echocardiographyen_US
dc.title.alternativeتقيين وظيفة البطين الأيسر لورضي الاستصفاء الدهوي باستخدام الووجات الصوتية علي القلب عبر الصدرen_US
dc.typeThesisen_US
Appears in Collections:PhD theses :Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Left ... .pdfResearch3.32 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.