Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/22182
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbdullah Abdulslam, Abdullah-
dc.contributor.authorShadia.A., Omer-
dc.date.accessioned2018-12-31T06:29:14Z-
dc.date.available2018-12-31T06:29:14Z-
dc.date.issued2018-12-30-
dc.identifier.citationAbdullah, Abdullah Abdulslam. Measurement of the Prothrombin Time, Activated partial thromboplastin time and Fibrinogen concentration in healthy dogs in Sudan/ Abdullah Abdulslam Abdullah, Shadia.A.Omer.- Journal of Science and technology vol 19, no 2.- article .en_US
dc.identifier.issn1858-6716-
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/22182-
dc.description.abstractThe aims of this study was to determine the mean values of prothrombin time (PT), activated partial thromboplastin time(APTT), and fibrinogen concentration(FIB) for healthy police dogs (Labrador Retriever (20) and,German Shepherd (26) ) in Sudan ,and to evaluate the effects of the breed and sex on these parameters. 46 male (21) and female (25) dogs aged between (20-83 months) were enrolled in the study. Blood samples(2ml) were taken from the cephalic vein in a tube containing 3.2% trisodium citrate.The analysis was performed using semiautomatic BCA-2000-LED-light-coagulometer-with-Double-channel and Spinreac reagents kits for human medicine. The overall mean values were 7.35±0.91second 15.12±1.32 second and 341.54±55.16 mg/dl for PT, APTT and fibrinogen concentration respectively. German Shepherd dogs showed significantly (P≤0.05) higher values than Labrador Retriever dogs for PT (7.58±1.01 vs 7.06±0.67) seconds respectively,and APTT (15.28 ±1.58 vs 14.9±0.85) seconds respectively.Males showed significantly (P≤0.05) higher values for FIB than the females (346.30±38.75 vs 337.73± 65.99) mg/dl respectively. Effect of breed should be considered in clinical interpretation of dog PT and APTT, also effect of sex should be considered in clinical interpretation of dog FIB.The determined reference values may be useful information for an increasing clinical use.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectProthrombin time (PT)en_US
dc.subjectActivated Partial Thromboplastine Time (APTT)en_US
dc.subjectFibrinogen concentration (FIB)en_US
dc.subjectsexen_US
dc.subjectbreeden_US
dc.titleMeasurement of the Prothrombin Time, Activated partial thromboplastin time and Fibrinogen concentration in healthy dogs in Sudanen_US
dc.typeArticleen_US
Appears in Collections:Volume 19 No. 2

Files in This Item:
File Description SizeFormat 
MEASUREMENT5.pdfarticle301.38 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.