Please use this identifier to cite or link to this item:
https://repository.sustech.edu/handle/123456789/19923
Title: | EXPERIMENTAL ASSESSMENT OF INDOOR ENVIRONMRNTAL QUALITY IN STUDIES HALL |
Other Titles: | تقييم عملي لجودة البيئة الداخلية في القاعات الدراسية |
Authors: | Ahmed, Al-Hassan Fadl Alatti Al-Hassan Mohamed, El-Moez Elgenaid Elamin Mohammed, Mohammed Omer Abdalwahab Supervisor-, .A.A.A.Abuelnuor |
Keywords: | QUALITY IN STUDIES HALL |
Issue Date: | 1-Oct-2017 |
Publisher: | Sudan University of Science and Technology |
Citation: | Ahmed, Al-Hassan Fadl Alatti Al-Hassan.EXPERIMENTAL ASSESSMENT OF INDOOR ENVIRONMRNTAL QUALITY IN STUDIES HALL/Al-Hassan Fadl Alatti Al-Hassan Ahmed,El-Moez Elgenaid Elamin Mohamed,Mohammed Omer Abdalwahab Mohammed;A.A.A.Abuelnuor.-Khartoum : Sudan University of Science and Technology, College of Engineering,2017.-60 p. :ill;28cm.- Bachelors search. |
Abstract: | Indoor environment of buildings has attracted increasing attention. Therefore ,advanced building technologies are essential not only for reducing energy consumption , but also for creating a comfortable and healthy indoor environment for buildings by measuring the rate of temperature , humidity and air velocity . Thermal comfort in study halls has lately been receiving more research attention because healthy environment has a big impact on students health and concentration and this experimental has been done in schools and universities in khartoum state . .This research shows the results of experimental study about indoor thermal comfort , based on investigation in Khartoum secondary schools . Different devices were used to take the measures . The animometer was used to measure the velocity of air and digital device was used to measure the rate of temperature and humidity in different locations inside the class depends on the location of teachers and students in class . Also the outdoor air temperature and humidity were measured to compare between inside and outside environment , temperature in public school between 35.8-36.2°C and the private school have ranged between 28.2-29.3°C the main goal of this study is to assessment indoor air quality inside class rooms . After analyzing these results we found that the majority of school environment is not suitable for students and study. |
Description: | Bachelors search |
URI: | http://repository.sustech.edu/handle/123456789/19923 |
Appears in Collections: | Bachelor of Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
EXPERIMENTAL ASSESSMENT OF INDOOR.pdf | Search | 1.72 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.