Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/19162
Title: Automatic Analysis’s of SPECT Gamma Camera performance using Image Processing
Other Titles: التحليل الآلي لأداء جهاز الجاما كاميرا باستخدام معالجة الصور
Authors: Ahmed, Einas Mohamed
Supervisor, -Mohamed Elfadil
Keywords: Medical Radiologic Sciences
Medical Physics
Automatic Analysis’s
SPECT Gamma Camera performance
Issue Date: 11-Sep-2017
Publisher: Sudan University of Science and Technology
Citation: Ahmed, Einas Mohamed . Automatic Analysis’s of SPECT Gamma Camera performance using Image Processing \ Einas Mohamed Ahmed ; Mohamed Elfadil .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2017.- 110 p.:ill.;28cm.-Ph.D
Abstract: The main objective of this study was to assess the quality control of SPECT gamma camera using developed Algorithm via image processing procedure. Usually assessment done through visual inspection of phantom images i.e. visual perception trend; in this study separate algorithm were developed to quantify the uniformity (integral, and differential), linearity and resolution using Modulation Transfer Function (MTF). The data of this study were collected from Royal Care International Hospital, Nuclear Medicine Department in the period from 2014 to 2016; images of QC test were taken from SPECT gamma camera as DICOM format. The result of this study showed that the uniformity for useful central field of view for integral uniformity was 2.97%. While row differential uniformity was 1.96% and column differential uniformity was 1.55% similar to build in routine. The linearity showed that for vertical location the variation from the original location of the line it was 0.02 mm which indicates that almost the point’s falls in the line with a correlation coefficient of 0.998. For horizontal lines the differences between the two in average equal to 0.2mm, with a correlation coefficient equal to 0.956. The resolution for minimum object used 4mm was 70% and increased with object size increased to reach 100% resolution for an object size of 10 mm i.e. 100% resolution corresponds to the coordinate of the MTF at 10% and frequency of 0.05cycle /mm. in conclusion the developed algorithm can be used to assess all gamma camera QC image regardless of the machine brand objectively
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/19162
Appears in Collections:PhD theses :Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Automatic Analysis’s of SPECT ... .pdfResearch1.4 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.