Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/16134
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGAAFAR,BAKRI ABDELRAHIM
dc.date.accessioned2017-04-18T07:52:16Z
dc.date.available2017-04-18T07:52:16Z
dc.date.issued2002
dc.identifier.citationGAAFAR,BAKRI ABDELRAHIM.UPGRADED TEMPERATURE MATCHED CURING SYSTEM/BAKRI ABDELRAHIM GAAFAR.Journal of Science and Technology.-vol3,no1.- 2002.-artical.en_US
dc.identifier.issnISSN 1605-427X
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/16134
dc.descriptionarticleen_US
dc.description.abstractA computer controlled temperature matched curing system to simulate curing of concrete in structures is presented. The system has capability to accurately control ambient temperature against hydration temperature generated by a fully insulated concrete specimens. Also it is capable of simulating any cooling rate which might occur on site and which depends on thickness of concrete element, type of formwork, ambient temperature, humidity and wind velocity Data of concrete of different compositions used at 20 C and 5 C and 35 C are compared with data of concrete cured using semiadiabatic conditions and effect of simulating cooling-time curve is discussed on light of results of strength porosity and permeabitlity. The influence of fly ash on properties of concrete cured at the different environments is also highlighted.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoen_USen_US
dc.publisherSudan University of Science and Technologyen_US
dc.titleUPGRADED TEMPERATURE MATCHED CURING SYSTEMen_US
dc.typeArticleen_US
Appears in Collections:Volume 3 No. 1

Files in This Item:
File SizeFormat 
l PGRADF.D TEMPERATURE...pdf1.65 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.