Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/16018
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMubarak, Riham Gamal Eldeen Adam-
dc.date.accessioned2017-04-05T14:17:36Z-
dc.date.available2017-04-05T14:17:36Z-
dc.date.issued2016-10-01-
dc.identifier.citationMubarak, Riham Gamal Eldeen Adam. Estimation of patient's radiation diagnostic doses in nuclear medicine\ Riham Gamal Eldeen Adam Mubarak. - Khartoum: Sudan University for Science and Technology, College of Science, 2016.- 44p. :ill ;28cm .- Bachelor Searchen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/16018-
dc.descriptionBachelor Searchen_US
dc.description.abstractThis study intends to estimate the patients radiation diagnostic doses in nuclear medicine. A total of 60 patients were examined in two Hospitals. The data were collected using a sheet for all patients in order to maintain consistency of the information. The following parameters were recorded age, weight and height to estimate the dose for thyroid scan, renal scan and bone scan. The examinations were collected according to the availability. The mean age, weight and height are 77.37, 66.76 and 1.64 respectively for male in elneelian center.The mean age, weight and height are 59.70, 67.86 and 1.61 respectively for female in elneelain center. The mean age, weight and height are 70.17, 69.34 and 1.62 respectively for male in elmek nimer hospital. The mean age, weight and height are 51.33, 62.40 and 1.68 respectively for female in elmek nimer hospital The mean doses of thyroid, renal and bone scan are 5.04, 9.19 and 20.10 respectively in elneelain center. The mean doses of thyroid, renal and bone scan are 5.24, 8.05 and 22.10 respectively in elmek nimer hospital. Patient doses were measuring during this study used on two hospitals to three types of organ diagnosed. demographic data (age, weight, height, sex, clinical indication, and type of organ diagnosed) were meausured. Dose calibrator were used to measure organ doses. Two different gamma camera machines were used throughout this study. In this study bone scan doses values were higher than the other two types of diagnosed while thyroid scan diagnosed is lowest one.en_US
dc.description.sponsorshipSudan University for Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University for Science and Technologyen_US
dc.subjectlaboratories- Physicsen_US
dc.subjectnuclear medicineen_US
dc.subjectEstimation of patient'sen_US
dc.titleEstimation of patient's radiation diagnostic doses in nuclear medicineen_US
dc.title.alternativeتقييم الجرعة الاشعاعية التشخيصية للمرضى ف الطب النوويen_US
dc.typeThesisen_US
Appears in Collections:Bachelor of Science

Files in This Item:
File Description SizeFormat 
Estimation of patient's radiation diagnostic doses in nuclear medicine.pdf1.35 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.