Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/15719
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFaris, Ayad Nabil
dc.contributor.authorSupervisor,- Ahmed Mostafa Abukonna
dc.date.accessioned2017-03-09T06:21:36Z
dc.date.available2017-03-09T06:21:36Z
dc.date.issued2016-09-18
dc.identifier.citationFaris, Ayad Nabil . Assessment of Radiation Dose Received during Thoraco-lumbar and Skull Examinations in Red Sea State Medical centers \ Ayad Nabil Faris ; Ahmed Mostafa Abukonna .- Kartoum:Sudan University of Science and Technology,Medical Radiologic Sciences,2016.-57p:ill;28cm.-M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/15719
dc.descriptionThesisen_US
dc.description.abstractThe main objective of this study was to assess patient dose during x-ray examination of skull and thoraco-lumbar in Red Sea state Hospitals. The dose received by 146 adult patients was measured using CALDOSE software by entering the parameters: focus to detector distance FDD, mAs , KVP. The result of the study showed that the mean of ESAK were found to be (0.79 ± 0.30) for skull and (0.37 ± 0.2) for thoraco-lumbar. The INAK were found to be (0.52 ± 0.14) for thoracic lumbar and (0.67 ± 0.25) for skull. The RCI were found to be (0.39 ± 0.19) for skull and (1.04 ± 0.75) for thoraco-lumbar. The mean ESAK values obtained are found to be within the standardreference. The data obtained may add to the available information in nationalrecords for general use. It may provide guidance on where efforts on dosereduction will need to be directed to fulfill the requirements of the optimizationprocess and serve as a reference for future researches.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectMedical Physicsen_US
dc.subjectRadiation Doseen_US
dc.subjectThoraco-lumbar and Skullen_US
dc.titleAssessment of Radiation Dose Received during Thoraco-lumbar and Skull Examinations in Red Sea State Medical centersen_US
dc.title.alternativeتقييم الجرعة الاشعاعية اثناء فحص الجمجمة و الفقرات القطنية في المراكز الطبية بولاية البحر الاحمرen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Radiation ....pdfResearch842.53 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.