dc.identifier.citationAbdullah,Yousif Mohamed Yousif.Evaluation of Chest Organ Motion in External Radiotherapy/Yousif Mohamed YousifAbdullah;Khalid Hassan Eltom .- khartoum :Sudan University of Science and Technology,Medical Radiology Scince,2013 .-162p. ;28 cm .-M.sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/1510
dc.descriptionThesisen_US
dc.description.abstractOrgan motion in Radiotherapy induces an error in dose received by the tumor therefore this experimental study conducted to evaluate the organs motion in external beam radiotherapy. The study was conducted at different hospitals in Sudan ; (Radiation and Isotopes center of Khartoum (RICK), National Cancer Institute (NCI), Elrabit Teaching Hospital, Fadial specialized Hospital, Shandi Teaching Hospital and Elnilien Medical Center in the period of January 2010 to May 2012. This is an experimental study deals with detection, measurement and analysis of the periodic physiological organ motion during external beam radiotherapy; to improve the accuracy of the radiation field placement, and to reduce the exposure of healthy tissue during radiation treatments. The importance of this study is to detect the maximum path of the mobile structures during radiotherapy delivery, to define the planning target volume (PTV) and irradiated volume during both inspiration and expiration period and to verify the target volume. In addition to its role to highlight the importance of the application of Intense Guided Radiotherapy (IGRT) methods in the field of radiotherapy. The results showed (body contour was equally (3.17 + 0.23 mm), for left lung displacement reading (2.56 + 0.99 mm) and right lung is (2.42 + 0.77 mm) which the radiation oncologist to take suitable countermeasures in case of significant errors. In addition, the use of the image registration technique for automatic position control is predicted potential motion. The motion ranged between 2.13 mm and 12.2 mm (low and high). In conclusion, individualized assessment of tumor mobility can improve the accuracy of target areas definition in patients undergo Sterostatic RT for stage I, II and III lung cancer (NSCLC). Definition of the target volume based on a single CT scan with a margin of 10 mm is clearly inappropriate.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoThesisen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectchesten_US
dc.subjectimagingen_US
dc.titleEvaluation of Chest Organ Motion in External Radiotherapyen_US
dc.typeThesisen_US
Appears in Collections:PhD theses :Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Abbreviation.pdfAbbreviation39.89 kBAdobe PDFView/Open
Abstract.pdfAbstract27.14 kBAdobe PDFView/Open
Evaluation of Chest .....pdfTitle55.76 kBAdobe PDFView/Open
Final Thesis.pdf
  Restricted Access
Research2.51 MBAdobe PDFView/Open Request a copy
Table of Contents.pdfContents52.94 kBAdobe PDFView/Open
Table of Figuress.pdfFiguress38.57 kBAdobe PDFView/Open
Table of Tables.pdfTables31.46 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.