Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/14208
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOmer, Abazar Mohamed Suliman
dc.contributor.authorSupervisor,- Mohamed Elfadil Mohamed
dc.date.accessioned2016-09-26T09:00:03Z
dc.date.available2016-09-26T09:00:03Z
dc.date.issued2016-04-18
dc.identifier.citationOmer , Abazar Mohamed Suliman . Characterization of Cardiac Abnormality in Single Photon Emission Computed Tomography Images Using Image Processing Technique \ Abazar Mohamed Suliman Omer ; Mohamed Elfadil Mohamed .- Khartoum:Sudan University of Science and Technology,College of Medical Radiologic Sciences,2016.-53p:ill;28cm.-M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/14208
dc.descriptionThesisen_US
dc.description.abstractThis study consists of 51 patient's different age, sex whom were referred to cardiology clinic for myocardial perfusion scintigraphy. To identify the percentage of the functioning areas of the heart by computer programthe study was also designed to code the heart SPECT image according to the function, differentiate between normal & abnormal area and To measure the size of the heart and the defected area. The patient underwent myocardial perfusion rest and stress scan taken after 30-40min, 50-60min respectively by acquiring 32 frames at 30sec/projectionwith the patients in supine position, in addition that in stress test the patients were injected with the pharmacological stress Persantine (0.567*patient weight) diluted with normal saline to have a total volume of 20ml. The study was conducted at International medical center (IMC) in SAUDIA ARABIA, JADDAH. Between(Oct2013-May2014). The results showed that there is a significant difference between the functioning percentage of the heart at rest and stress concerning the mild and moderate classification of heart perfusion reduction.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologicen_US
dc.subjectnuclear Medicine technologyen_US
dc.subjectImage Processing Techniqueen_US
dc.subjectCardiac Abnormalityen_US
dc.titleCharacterization of Cardiac Abnormality in Single Photon Emission Computed Tomography Images Using Image Processing Techniqueen_US
dc.title.alternativeتوصيف أمراض التشوهات القلبية فى التصوير المقطعي بالفوتون الآحادى بإستخدام تقنية معالجة الصورen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Characterization of Cardiac ............pdfTitle70.74 kBAdobe PDFView/Open
Research.pdfResearch1.79 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.