Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/1362
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSalih, ahlam Hassan
dc.contributor.authorSupervisor - Mohamed Ahmed Ali Omer
dc.contributor.author
dc.date.accessioned2013-08-27T08:22:25Z
dc.date.available2013-08-27T08:22:25Z
dc.date.issued2012-01-01
dc.identifier.citationsalih, ahlam hassan .Assessment of co-60 Radiation teletherapy unit performance in Radiation and isotope center khartoum /ahlam hassan Salih ; Mohammed Ahmed Ali .-Khartoum:sudan university of scince and technololgy,Medical Radiologic scince,2012.-28p. :ill .;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/1362
dc.descriptionThesisen_US
dc.description.abstractThe current study carried out in Radiation and Isotopes Center in Khartoum to assess 60Co-teletherapy unit performance, in which they the front pointer, graphic paper, Pin, non screen film and check plate were used to obtain the measurements. The results reveal that there is a difference between the theoretical FS and the measured one in relation to the change of SSD; and the average difference was 1.1 cm Also from the correlation between the QC field size (practical measurement) and inverse square low (theoretical) field size which is given by using Myneord Factor, there is 0.4 cm as excess value in practical measurement relative to theoretical method. Also there were shift in the collimator, couch and gantry angel isocenter versus variability in SSD, angel of diaphragm rotation respectively which was ±1.1, ±1.3, 0.003 cm respectively. Also the study reveal that the scale meter SSD has a shift of 0.8 cm greater than the actual measured one and determined by front pointer. Moreover the scanning of the exposed film revealed that the penumbra profile was 2 cm and the laser beams incongruence at the isocenter was 1.1 cm.en_US
dc.description.sponsorshipSudan university of science and technologyen_US
dc.language.isoenen_US
dc.publishersudan Universty of science and technologyen_US
dc.subjectRadioation teletherapyen_US
dc.titleAssessment of co-60 radiation telethe rapy Unit perfamance in radiation and isotope center khartoumen_US
dc.typeThesisen_US
Appears in Collections:PhD theses :Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Co-60 Radiation... .pdfTitle64.32 kBAdobe PDFView/Open
Abstract.pdfAbstract324.48 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research853.4 kBAdobe PDFView/Open Request a copy
Appendix.pdfAppendix17.73 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.